BIOCLEAR VIDEO TUTORIAL

How to Use the Bioclear Adjustable Push-Pull

A practical guide to matrix adaptation and contact development using the Bioclear Adjustable Push-Pull Instrument.

Achieving appropriate proximal contacts and anatomical contours is an important part of successful posterior composite restorations.

The Bioclear Adjustable Push-Pull has been designed to assist clinicians with the positioning and adaptation of posterior anatomical matrices, including the Evolve matrix system.

Its adjustable mechanism and dual-ended design provide different options for working with premolars, molars and smaller cavity preparations.

Bioclear Adjustable Push-Pull Instrument showing the numbered adjustment slider and instrument tips
Bioclear Adjustable Push-Pull
Adjustable posterior matrix adaptation instrument featuring numbered settings and rounded working tips.
INSTRUCTIONAL VIDEO

Watch: Adjustable Push-Pull Instrument

See the instrument and its different adjustment options for posterior matrix adaptation.

What Is the Adjustable Push-Pull?

A dual-ended instrument designed to help clinicians position and adapt anatomical matrices during posterior composite restorations.

01

Adjustable Working End

A numbered sliding adjustment allows the clinician to adapt the working end for different posterior tooth widths and matrix configurations.

02

Dual-Ended Design

The instrument includes an adjustable end and an additional working end for smaller preparations and more restricted areas.

03

Rounded Working Tips

Rounded tips are designed to assist with controlled matrix positioning while reducing the risk of damaging the matrix.

04

Evolve Matrix Compatibility

The adjustable mechanism is intended for use with posterior anatomical matrices, including the Bioclear Evolve range.

05

Push & Pull Adaptation

The instrument supports both pushing and pulling movements to help guide the matrix into the desired contact position.

06

Stainless Steel Construction

Manufactured from stainless steel for repeated use within the appropriate cleaning and sterilisation protocols.

What makes it different?
Unlike a conventional fixed-width adaptation instrument, the adjustable Push-Pull allows the working width to be selected according to the posterior tooth and matrix being used.

Understanding the Adjustable Settings

The instrument's numbered guide helps clinicians select an appropriate working width for different posterior restorative situations.

4.5 PREMOLARS

Smaller Posterior Teeth

The smaller adjustment is intended for premolars and narrower posterior restorative situations.

Useful where the available space and anatomical dimensions require a narrower working width.

7–8 WIDE MOLARS

Wider Posterior Contacts

The wider settings can be selected for broader molar anatomy and larger matrix configurations.

The original tutorial highlights their use with the Orange Evolve matrix.

Important:
These settings are a guide to instrument adjustment, not a substitute for selecting the correct matrix or confirming its clinical fit. The appropriate position depends on tooth anatomy, preparation dimensions and the intended contact relationship.

Understanding Push & Pull Adaptation

The instrument provides controlled ways to help position the matrix against the adjacent tooth and establish the intended proximal contour.

TECHNIQUE 01

PUSH

The working end can be used to apply controlled pressure to the matrix, helping move it towards the desired contact position.

The objective is to support appropriate matrix adaptation without creating unnecessary distortion.

TECHNIQUE 02

PULL

The alternative movement allows the clinician to engage and guide the matrix from a different direction.

This can be useful when the preparation, adjacent tooth or available access makes conventional adaptation more challenging.

Clinical principle:
The goal is to achieve the intended contact position and matrix adaptation before the main restorative material is placed. The precise movement and instrument setting should be selected according to the clinical situation.

What About Small Preparations?

Not every posterior restoration requires the adjustable end of the instrument.

01

Fixed Small Working End

The instrument's smaller, non-adjustable working end provides another option for restricted access and compact cavity preparations.

02

Small Preparations & Diastema Closure

For very small preparations or selected posterior diastema closures, the original tutorial also discusses using the smaller end or a convex Bioclear paddle instrument.

Where Does the Push-Pull Fit in the Clinical Workflow?

Matrix adaptation is one stage within a complete Class II restorative procedure.

01

Select the Matrix

Choose an appropriate posterior matrix based on tooth anatomy, cavity dimensions and the intended emergence profile.

02

Position & Stabilise

Seat the matrix and use the appropriate wedge and separation system for the clinical situation.

03

Adapt the Matrix

Use the Push-Pull to help position the matrix against the adjacent tooth and develop the desired contact area.

04

Restore & Verify

Continue with the selected restorative protocol, then assess the final contact, anatomy and marginal adaptation.

Spot Weld technique:
The Push-Pull can also be used alongside the Bioclear Spot Weld technique, where flowable composite is used to stabilise the matrix in the intended contact position. Correct matrix placement and the full restorative protocol remain essential.

Bioclear Adjustable Push-Pull Instrument
BIOCLEAR CLINICAL EQUIPMENT

Adjustable Push-Pull Instrument

Designed for posterior matrix adaptation with the Bioclear Method.

Featuring a numbered adjustable mechanism, dual-ended functionality and rounded working tips, the instrument provides additional flexibility when positioning posterior anatomical matrices.

Suitable for use with Bioclear Evolve and Biofit posterior matrix systems.

Sign in to your Bioclear UK account to view product pricing.

Frequently Asked Questions

Practical questions about the Bioclear Adjustable Push-Pull.

What is the Bioclear Adjustable Push-Pull used for?

The instrument is designed to assist with positioning and adapting posterior anatomical matrices during direct composite restorations.

Which matrices can I use with the Push-Pull?

The instrument is designed for use with the Bioclear Evolve and Biofit posterior matrix systems.

Which setting should I use for a premolar?

The original tutorial describes the 4.5 setting for narrower posterior situations, including premolars.

The appropriate setting must still be selected according to the tooth and matrix being used.

What settings are used for molars?

The tutorial describes settings 5–6 for standard molars and 7–8 for wider molars.

These are guides rather than fixed rules for every clinical situation.

Can I use the Push-Pull for small preparations?

Yes. The instrument includes a smaller working end intended for compact cavity preparations and restricted spaces.

Does the Push-Pull replace separation rings and wedges?

No. The Push-Pull is an adaptation instrument.

Appropriate matrix selection, wedging, tooth separation and restorative technique remain important for Class II contact development.

Can it be used with the Spot Weld technique?

Yes. The product information recommends pairing the instrument with the Bioclear Spot Weld technique for selected posterior restorations.

Where can I learn posterior Bioclear techniques?

Bioclear Matrix UK offers hands-on education covering posterior anatomical matrices, Class II restorations, contact development and heated composite injection moulding.

BIOCLEAR HANDS-ON EDUCATION

Master Posterior Matrix Adaptation

Understanding the instruments is only part of developing confidence with posterior composite restorations.

Our Bioclear Introduction and Core Posterior courses cover anatomical matrix selection, Class II contacts, contemporary cavity preparation and heated composite injection moulding.

Explore Bioclear Courses →
Back to blog